Attributes { DATA_TYPE { String _FillValue " "; String long_name "Data type"; String conventions "Argo reference table 1"; Int32 string_length 32; } FORMAT_VERSION { String _FillValue " "; String long_name "File format version"; Int32 string_length 4; } HANDBOOK_VERSION { String _FillValue " "; String long_name "Data handbook version"; Int32 string_length 4; } REFERENCE_DATE_TIME { String _FillValue " "; String long_name "Date of reference for Julian days"; String conventions "YYYYMMDDHHMISS"; Int32 string_length 14; } DATE_CREATION { String _FillValue " "; String long_name "Date of file creation"; String conventions "YYYYMMDDHHMISS"; Int32 string_length 14; } DATE_UPDATE { String _FillValue " "; String long_name "Date of update of this file"; String conventions "YYYYMMDDHHMISS"; Int32 string_length 14; } PLATFORM_NUMBER { String _FillValue " "; String long_name "Float unique identifier"; String conventions "WMO float identifier : A9IIIII"; Int32 string_length 8; } PROJECT_NAME { String _FillValue " "; String long_name "Name of the project"; Int32 string_length 64; } PI_NAME { String _FillValue " "; String long_name "Name of the principal investigator"; Int32 string_length 64; } STATION_PARAMETERS { String _FillValue " "; String long_name "List of available parameters for the station"; String conventions "Argo reference table 3"; Int32 string_length 64; } CYCLE_NUMBER { Int32 _FillValue 99999; String long_name "Float cycle number"; String conventions "0...N, 0 : launch cycle (if exists), 1 : first complete cycle"; } DIRECTION { String _FillValue " "; String long_name "Direction of the station profiles"; String conventions "A: ascending profiles, D: descending profiles"; Int32 string_length 230; } DATA_CENTRE { String _FillValue " "; String long_name "Data centre in charge of float data processing"; String conventions "Argo reference table 4"; Int32 string_length 2; } PARAMETER_DATA_MODE { String _FillValue " "; String long_name "Delayed mode or real time data"; String conventions "R : real time; D : delayed mode; A : real time with adjustment"; Int32 string_length 14; } PLATFORM_TYPE { String _FillValue " "; String long_name "Type of float"; String conventions "Argo reference table 23"; Int32 string_length 32; } FLOAT_SERIAL_NO { String _FillValue " "; String long_name "Serial number of the float"; Int32 string_length 32; } FIRMWARE_VERSION { String _FillValue " "; String long_name "Instrument firmware version"; Int32 string_length 32; } WMO_INST_TYPE { String _FillValue " "; String long_name "Coded instrument type"; String conventions "Argo reference table 8"; Int32 string_length 4; } JULD { Float64 _FillValue 999999.0000000000; String long_name "Julian day (UTC) of the station relative to REFERENCE_DATE_TIME"; String standard_name "time"; String units "days since 1950-01-01 00:00:00 UTC"; String conventions "Relative julian days with decimal part (as parts of day)"; String axis "T"; Float64 resolution 0.0006944444444444445; } JULD_QC { String _FillValue " "; String long_name "Quality on date and time"; String conventions "Argo reference table 2"; Int32 string_length 230; } JULD_LOCATION { Float64 _FillValue 999999.0000000000; String long_name "Julian day (UTC) of the location relative to REFERENCE_DATE_TIME"; String units "days since 1950-01-01 00:00:00 UTC"; String conventions "Relative julian days with decimal part (as parts of day)"; Float64 resolution 1.157407407407407e-05; } LATITUDE { Float64 _FillValue 99999.00000000000; String long_name "Latitude of the station, best estimate"; String standard_name "latitude"; String units "degree_north"; Float64 valid_min -90.00000000000000; Float64 valid_max 90.00000000000000; String axis "Y"; } LONGITUDE { Float64 _FillValue 99999.00000000000; String long_name "Longitude of the station, best estimate"; String standard_name "longitude"; String units "degree_east"; Float64 valid_min -180.0000000000000; Float64 valid_max 180.0000000000000; String axis "X"; } POSITION_QC { String _FillValue " "; String long_name "Quality on position (latitude and longitude)"; String conventions "Argo reference table 2"; Int32 string_length 230; } POSITIONING_SYSTEM { String _FillValue " "; String long_name "Positioning system"; Int32 string_length 8; } CONFIG_MISSION_NUMBER { Int32 _FillValue 99999; String long_name "Unique number denoting the missions performed by the float"; String conventions "1...N, 1 : first complete mission"; } PARAMETER { String _FillValue " "; String long_name "List of parameters with calibration information"; String conventions "Argo reference table 3"; Int32 string_length 64; } SCIENTIFIC_CALIB_EQUATION { String _FillValue " "; String long_name "Calibration equation for this parameter"; Int32 string_length 256; } SCIENTIFIC_CALIB_COEFFICIENT { String _FillValue " "; String long_name "Calibration coefficients for this equation"; Int32 string_length 256; } SCIENTIFIC_CALIB_COMMENT { String _FillValue " "; String long_name "Comment applying to this parameter calibration"; Int32 string_length 256; } SCIENTIFIC_CALIB_DATE { String _FillValue " "; String long_name "Date of calibration"; String conventions "YYYYMMDDHHMISS"; Int32 string_length 14; } PROFILE_PRES_QC { String long_name "Global quality flag of PRES profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_TEMP_QC { String long_name "Global quality flag of TEMP profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_PSAL_QC { String long_name "Global quality flag of PSAL profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_DOXY_QC { String long_name "Global quality flag of DOXY profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_DOWN_IRRADIANCE380_QC { String long_name "Global quality flag of DOWN_IRRADIANCE380 profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_DOWN_IRRADIANCE412_QC { String long_name "Global quality flag of DOWN_IRRADIANCE412 profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_DOWN_IRRADIANCE490_QC { String long_name "Global quality flag of DOWN_IRRADIANCE490 profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_DOWNWELLING_PAR_QC { String long_name "Global quality flag of DOWNWELLING_PAR profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_CHLA_QC { String long_name "Global quality flag of CHLA profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_CHLA_FLUORESCENCE_QC { String long_name "Global quality flag of CHLA_FLUORESCENCE profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_BBP700_QC { String long_name "Global quality flag of BBP700 profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_CDOM_QC { String long_name "Global quality flag of CDOM profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_PH_IN_SITU_TOTAL_QC { String long_name "Global quality flag of PH_IN_SITU_TOTAL profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PROFILE_NITRATE_QC { String long_name "Global quality flag of NITRATE profile"; String conventions "Argo reference table 2a"; String _FillValue " "; Int32 string_length 230; } PRES { String long_name "Sea water pressure, equals 0 at sea-level"; String standard_name "sea_water_pressure"; Float32 _FillValue 99999.0000; String units "decibar"; Float32 valid_min 0.00000000; Float32 valid_max 12000.0000; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; String axis "Z"; } PRES_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } PRES_ADJUSTED { String long_name "Sea water pressure, equals 0 at sea-level"; String standard_name "sea_water_pressure"; Float32 _FillValue 99999.0000; String units "decibar"; Float32 valid_min 0.00000000; Float32 valid_max 12000.0000; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; String axis "Z"; } PRES_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } PRES_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "decibar"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } TEMP { String long_name "Sea temperature in-situ ITS-90 scale"; String standard_name "sea_water_temperature"; Float32 _FillValue 99999.0000; String units "degree_Celsius"; Float32 valid_min -2.50000000; Float32 valid_max 40.0000000; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } TEMP_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } TEMP_dPRES { String long_name "TEMP pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } TEMP_ADJUSTED { String long_name "Sea temperature in-situ ITS-90 scale"; String standard_name "sea_water_temperature"; Float32 _FillValue 99999.0000; String units "degree_Celsius"; Float32 valid_min -2.50000000; Float32 valid_max 40.0000000; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } TEMP_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } TEMP_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "degree_Celsius"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } PSAL { String long_name "Practical salinity"; String standard_name "sea_water_salinity"; Float32 _FillValue 99999.0000; String units "psu"; Float32 valid_min 2.00000000; Float32 valid_max 41.0000000; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 9.99999975e-05; } PSAL_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } PSAL_dPRES { String long_name "PSAL pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } PSAL_ADJUSTED { String long_name "Practical salinity"; String standard_name "sea_water_salinity"; Float32 _FillValue 99999.0000; String units "psu"; Float32 valid_min 2.00000000; Float32 valid_max 41.0000000; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 9.99999975e-05; } PSAL_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } PSAL_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "psu"; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 9.99999975e-05; } DOXY { String long_name "Dissolved oxygen"; String standard_name "moles_of_oxygen_per_unit_mass_in_sea_water"; Float32 _FillValue 99999.0000; String units "micromole/kg"; Float32 valid_min -5.00000000; Float32 valid_max 600.000000; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } DOXY_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } DOXY_dPRES { String long_name "DOXY pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } DOXY_ADJUSTED { String long_name "Dissolved oxygen"; String standard_name "moles_of_oxygen_per_unit_mass_in_sea_water"; Float32 _FillValue 99999.0000; String units "micromole/kg"; Float32 valid_min -5.00000000; Float32 valid_max 600.000000; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } DOXY_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } DOXY_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "micromole/kg"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } DOWN_IRRADIANCE380 { String long_name "Downwelling irradiance at 380 nanometers"; Float32 _FillValue 99999.0000; String units "W/m^2/nm"; String C_format "%.6f"; String FORTRAN_format "F.6"; Float32 resolution 9.99999997e-07; } DOWN_IRRADIANCE380_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } DOWN_IRRADIANCE380_dPRES { String long_name "DOWN_IRRADIANCE380 pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } DOWN_IRRADIANCE380_ADJUSTED { String long_name "Downwelling irradiance at 380 nanometers"; Float32 _FillValue 99999.0000; String units "W/m^2/nm"; String C_format "%.6f"; String FORTRAN_format "F.6"; Float32 resolution 9.99999997e-07; } DOWN_IRRADIANCE380_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } DOWN_IRRADIANCE380_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "W/m^2/nm"; String C_format "%.6f"; String FORTRAN_format "F.6"; Float32 resolution 9.99999997e-07; } DOWN_IRRADIANCE412 { String long_name "Downwelling irradiance at 412 nanometers"; Float32 _FillValue 99999.0000; String units "W/m^2/nm"; String C_format "%.6f"; String FORTRAN_format "F.6"; Float32 resolution 9.99999997e-07; } DOWN_IRRADIANCE412_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } DOWN_IRRADIANCE412_dPRES { String long_name "DOWN_IRRADIANCE412 pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } DOWN_IRRADIANCE412_ADJUSTED { String long_name "Downwelling irradiance at 412 nanometers"; Float32 _FillValue 99999.0000; String units "W/m^2/nm"; String C_format "%.6f"; String FORTRAN_format "F.6"; Float32 resolution 9.99999997e-07; } DOWN_IRRADIANCE412_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } DOWN_IRRADIANCE412_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "W/m^2/nm"; String C_format "%.6f"; String FORTRAN_format "F.6"; Float32 resolution 9.99999997e-07; } DOWN_IRRADIANCE490 { String long_name "Downwelling irradiance at 490 nanometers"; Float32 _FillValue 99999.0000; String units "W/m^2/nm"; String C_format "%.6f"; String FORTRAN_format "F.6"; Float32 resolution 9.99999997e-07; } DOWN_IRRADIANCE490_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } DOWN_IRRADIANCE490_dPRES { String long_name "DOWN_IRRADIANCE490 pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } DOWN_IRRADIANCE490_ADJUSTED { String long_name "Downwelling irradiance at 490 nanometers"; Float32 _FillValue 99999.0000; String units "W/m^2/nm"; String C_format "%.6f"; String FORTRAN_format "F.6"; Float32 resolution 9.99999997e-07; } DOWN_IRRADIANCE490_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } DOWN_IRRADIANCE490_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "W/m^2/nm"; String C_format "%.6f"; String FORTRAN_format "F.6"; Float32 resolution 9.99999997e-07; } DOWNWELLING_PAR { String long_name "Downwelling photosynthetic available radiation"; String standard_name "downwelling_photosynthetic_photon_flux_in_sea_water"; Float32 _FillValue 99999.0000; String units "microMoleQuanta/m^2/sec"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } DOWNWELLING_PAR_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } DOWNWELLING_PAR_dPRES { String long_name "DOWNWELLING_PAR pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } DOWNWELLING_PAR_ADJUSTED { String long_name "Downwelling photosynthetic available radiation"; String standard_name "downwelling_photosynthetic_photon_flux_in_sea_water"; Float32 _FillValue 99999.0000; String units "microMoleQuanta/m^2/sec"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } DOWNWELLING_PAR_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } DOWNWELLING_PAR_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "microMoleQuanta/m^2/sec"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } CHLA { String long_name "Chlorophyll-A"; String standard_name "mass_concentration_of_chlorophyll_a_in_sea_water"; Float32 _FillValue 99999.0000; String units "mg/m3"; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 0.0250000004; } CHLA_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } CHLA_dPRES { String long_name "CHLA pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } CHLA_ADJUSTED { String long_name "Chlorophyll-A"; String standard_name "mass_concentration_of_chlorophyll_a_in_sea_water"; Float32 _FillValue 99999.0000; String units "mg/m3"; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 0.0250000004; } CHLA_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } CHLA_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "mg/m3"; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 0.0250000004; } CHLA_FLUORESCENCE { String long_name "Chlorophyll fluorescence with factory calibration"; Float32 _FillValue 99999.0000; String units "ru"; Float32 valid_min -0.200000003; Float32 valid_max 100.000000; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 0.0250000004; } CHLA_FLUORESCENCE_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } CHLA_FLUORESCENCE_dPRES { String long_name "CHLA_FLUORESCENCE pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } CHLA_FLUORESCENCE_ADJUSTED { String long_name "Chlorophyll fluorescence with factory calibration"; Float32 _FillValue 99999.0000; String units "ru"; Float32 valid_min -0.200000003; Float32 valid_max 100.000000; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 0.0250000004; } CHLA_FLUORESCENCE_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } CHLA_FLUORESCENCE_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "ru"; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 0.0250000004; } BBP700 { String long_name "Particle backscattering at 700 nanometers"; Float32 _FillValue 99999.0000; String units "m-1"; String C_format "%.7f"; String FORTRAN_format "F.7"; Float32 resolution 1.00000001e-07; } BBP700_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } BBP700_dPRES { String long_name "BBP700 pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } BBP700_ADJUSTED { String long_name "Particle backscattering at 700 nanometers"; Float32 _FillValue 99999.0000; String units "m-1"; String C_format "%.7f"; String FORTRAN_format "F.7"; Float32 resolution 1.00000001e-07; } BBP700_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } BBP700_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "m-1"; String C_format "%.7f"; String FORTRAN_format "F.7"; Float32 resolution 1.00000001e-07; } CDOM { String long_name "Concentration of coloured dissolved organic matter in sea water"; Float32 _FillValue 99999.0000; String units "ppb"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } CDOM_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } CDOM_dPRES { String long_name "CDOM pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } CDOM_ADJUSTED { String long_name "Concentration of coloured dissolved organic matter in sea water"; Float32 _FillValue 99999.0000; String units "ppb"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } CDOM_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } CDOM_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "ppb"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } PH_IN_SITU_TOTAL { String long_name "pH"; String standard_name "sea_water_ph_reported_on_total_scale"; Float32 _FillValue 99999.0000; String units "dimensionless"; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 9.99999975e-05; } PH_IN_SITU_TOTAL_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } PH_IN_SITU_TOTAL_dPRES { String long_name "PH_IN_SITU_TOTAL pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } PH_IN_SITU_TOTAL_ADJUSTED { String long_name "pH"; String standard_name "sea_water_ph_reported_on_total_scale"; Float32 _FillValue 99999.0000; String units "dimensionless"; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 9.99999975e-05; } PH_IN_SITU_TOTAL_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } PH_IN_SITU_TOTAL_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "dimensionless"; String C_format "%.4f"; String FORTRAN_format "F.4"; Float32 resolution 9.99999975e-05; } NITRATE { String long_name "Nitrate"; String standard_name "moles_of_nitrate_per_unit_mass_in_sea_water"; Float32 _FillValue 99999.0000; String units "micromole/kg"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } NITRATE_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } NITRATE_dPRES { String long_name "NITRATE pressure displacement from original sampled value"; Float32 _FillValue 99999.0000; String units "decibar"; } NITRATE_ADJUSTED { String long_name "Nitrate"; String standard_name "moles_of_nitrate_per_unit_mass_in_sea_water"; Float32 _FillValue 99999.0000; String units "micromole/kg"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } NITRATE_ADJUSTED_QC { String long_name "quality flag"; String conventions "Argo reference table 2"; String _FillValue " "; Int32 string_length 1026; } NITRATE_ADJUSTED_ERROR { String long_name "Contains the error on the adjusted values as determined by the delayed mode QC process"; Float32 _FillValue 99999.0000; String units "micromole/kg"; String C_format "%.3f"; String FORTRAN_format "F.3"; Float32 resolution 0.00100000005; } NC_GLOBAL { String title "Argo float vertical profile"; String institution "CORIOLIS"; String source "Argo float"; String history "2024-07-01T13:49:03Z creation (software version 1.18 (version 11.01.2024 for ARGO_simplified_profile))"; String references "http://www.argodatamgt.org/Documentation"; String user_manual_version "1.0"; String Conventions "Argo-3.1 CF-1.6"; String featureType "trajectoryProfile"; String software_version "1.18 (version 11.01.2024 for ARGO_simplified_profile)"; String id "https://doi.org/10.17882/42182"; } }